i have 2 debian linux servers with Dell openmanage 8.3. hardware is PowerEdge R410.
i used this repo:
deb linux.dell.com/.../ubuntu jessie openmanage
and installed paket "srvadmin-all"
however one server is not showing all information
when i do "omreport chassis" on server1 i get:
Health
Main System Chassis
SEVERITY : COMPONENT
Ok : Fans
Ok : Intrusion
Ok : Memory
Ok : Power Supplies
Ok : Power Management
Ok : Processors
Ok : Temperatures
Ok : Voltages
Ok : Hardware Log
Ok : Batteries
BUT on server2 i only get this information:
Health
Main System Chassis
SEVERITY : COMPONENT
Ok : Memory
Ok : Processors
so i.e. when i try "omreport chassis Fans" i get :
Error! No fan probes found on this system.
on Server1 its working correctly:
Fan Probes Information
Fan Redundancy
Redundancy Status : Full
Probe List
Index : 0
Status : Ok
Probe Name : System Board FAN MOD 1A RPM
Reading : 6840 RPM
Minimum Warning Threshold : [N/A]
Maximum Warning Threshold : [N/A]
Minimum Failure Threshold : 2640 RPM
Maximum Failure Threshold : [N/A]
...
do you have any ideas whats wrong with server2 ? is there maybe a paket missing that is not included in srvadmin-all ?
TIA
dave